A simplified version of the analyzer StatStrip Glucose with a minimal set of additional functions.
Analyzer StatStrip Xpress-i Glucose and ß-Ketone for in vitro diagnostic use in health care facilities for the quantitative analysis of glucose in fresh capillary, venous or arterial whole blood, as well as to quantitate ß-ketone (Rem) in fresh capillary and venous whole blood. Ability to work with neonatal blood.
Additional features:
- LCD black-and-white display;
- Large numbers (30 mm);
- Traditional quality control with preset values of reference materials;
- Auto-off device when it is simple;
- Automatic detection of sample in the analysis;
- Automatic counter samples with the date / time data tracking.
Specifications:
Data storage: Data of patients and quality control: 400 test.
Contact:
- Data Transfer: USB port;
- Program for working with data: NOVA Microsoft-Excel.
Battery Information: Type: 3V Li battery, replaceable.
Battery life: Minimum 600 tests.
Test strips StatStrip Glucose stripGlu
- Measurement tests: glucose, corrected for hematocrit;
- The output test: glucose;
- Analysis Time: 6 seconds;
- Sample volume: 1.2 L .;
- Test Methodology: electro.
Sample Type: Whole Blood: arterial, venous, capillary, neonatal.
Glucose Measurement range: 0.6-33.3 mmol / L.
Excludes the effect of:
- Hematocrit;
- Ascorbic acid;
- Uric acid;
- Acetaminophen (Paracetamol)
- Bilirubin;
- Maltose;
- galactose;
- Oxygen.
Operating range:
- Temperature: 15 ° C-40 ° C;
- Height: up to 15,000 feet;
- Humidity: 10% to 90% relative humidity.
- Hematocrit: 20-65%.
Reagents and strips:
- Test strips: 50 strips in each tube, the tube 2 in the package.
- Quality Control: Three levels (low, normal, high); each level is offered separately.
- Linearity: Five levels.
The stability of the test strips and quality control:
24 months from the date 90 days after opening.
Test strips StatStrip Ketone ketstrips
- Measurement Tests: ketones, adjusted for hematocrit;
- Output test: ketones;
- Analysis time: 10 seconds;
- Sample volume: 0.8 l;
- Test Methodology: electro.
Measuring range of ketones: 0.0-8.0 mmol / L.
Sample Type: Whole Blood: arterial, venous, capillary.
Operating range:
- Temperature: 15 ° C-40 ° C;
- Height: up to 15,000 feet;
- Humidity: 10% to 90% relative humidity;
- Hematocrit: 20-65%.
Reagents and strips:
- Test strips: 25 strips in each tube, the tube 2 in the package.
- Quality Control: Three levels (low, normal, high); each level is offered separately.
- Linearity: Five levels.
The stability of the test strips and quality control:
24 months from the date 90 days after opening.
* ß-hydroxybutyrate
Analyzer Size (mm): 91 x 58 x 23.
Weight analyzer: ’75
Manufacturer: NOVA Biomedical